# |
Title |
Pgs |
Photo |
Type |
File |
1 |
Order of Hearing: 1A |
1 |
0 |
Adobe PDF file |
View
|
2 |
Notice of Designation of Chairman of Board of Inquiry: 1B |
1 |
0 |
Adobe PDF file |
View
|
3 |
Designation of Hearing Officer: 1C |
1 |
0 |
Adobe PDF file |
View
|
4 |
Designation of Parties to the Hearing: 1D |
1 |
0 |
Adobe PDF file |
View
|
5 |
Notice of Hearing: 1E |
1 |
0 |
Adobe PDF file |
View
|
6 |
Hearing Exhibit List: 1F |
6 |
0 |
Adobe PDF file |
View
|
7 |
Witness List: 1G |
6 |
0 |
Adobe PDF file |
View
|
8 |
Operations Group Chairman's Factual Report - Exhibit 2A |
28 |
2 |
Adobe PDF file |
View
|
9 |
Exhibit 2B: PG&E Event Timeline |
5 |
0 |
Adobe PDF file |
View
|
10 |
Exhibit 2C: 49 CFR 192.619 (A)(3) and PG&E Documentation NTSB_011-011 |
5 |
0 |
Adobe PDF file |
View
|
11 |
Exhibit 2D: Schematic Showing Relative Locations of Nearby Services and L132 in the Trench |
2 |
0 |
Adobe PDF file |
View
|
12 |
Exhibit 2D - Updated: Schematic Showing Relatvie Locations of Nearby Services and L132 in the Trench |
1 |
0 |
Adobe PDF file |
View
|
13 |
Exhibit 2E: Former PG&E Employee Photograph Near Rupture Area |
2 |
0 |
Adobe PDF file |
View
|
14 |
Exhibit 2F: PG&E Retiree Interview |
45 |
0 |
Adobe PDF file |
View
|
15 |
Exhibit 2G: Milipitas Terminal One-line Diagram (NTSB 004-001) |
2 |
0 |
Adobe PDF file |
View
|
16 |
Exhibit 2H: SCADA Screenshot of Peninsula System & Milpitas to Martin & Milpitas Terminal |
4 |
0 |
Adobe PDF file |
View
|
17 |
Exhibit 2I: SCADA Alarms(NTSB 0014-008) |
97 |
0 |
Adobe PDF file |
View
|
18 |
Exhibit 2J: SCADA Alarm Policy NTSB 014-006 |
6 |
0 |
Adobe PDF file |
View
|
19 |
Exhibit 2K: SCADA Pressure Readings on 9-9-10 (16:12 Through 18:42) |
7 |
0 |
Adobe PDF file |
View
|
20 |
Exhibit 2L: Photo of Monitor Valve Pneumatic Controller |
2 |
0 |
Adobe PDF file |
View
|
21 |
Exhibit 2M: SCADA Pressure Transducer Locations (NTSB 036-004) |
4 |
0 |
Adobe PDF file |
View
|
22 |
Exhibit 2N: PG&E SCADA Trends from 9-9-10 |
6 |
0 |
Adobe PDF file |
View
|
23 |
Exhibit 2O: Excerpts from the PG&E ECDA Plan RMP-09 |
101 |
0 |
Adobe PDF file |
View
|
24 |
Exhibit 2P: PG&E Line 132Survey Sheets |
13 |
0 |
Adobe PDF file |
View
|
25 |
Exhibit 2Q: Senior Consulting Engineer RMP-06 Memo to File and Supporting Documents |
86 |
0 |
Adobe PDF file |
View
|
26 |
Exhibit 2R: 49CFR 192.903 |
3 |
0 |
Adobe PDF file |
View
|
27 |
Exhibit 2S: PG&E PIR AND HCA Drawings |
5 |
0 |
Adobe PDF file |
View
|
28 |
Exhibit 2T: Standard Cathodic Maintenance Report (NTSB 001-011) |
5 |
0 |
Adobe PDF file |
View
|
29 |
Exhibit 2T1: CPUC Waiver to PG&E for Bimonthly Rectifier Testing DOT 192.465 |
4 |
0 |
Adobe PDF file |
View
|
30 |
Exhibit 2U: Supervising Engineer for the ILI and DA Programs |
73 |
0 |
Adobe PDF file |
View
|
31 |
Exhibit 2V: January Interview of SCADA Controls Group Supervising Engineer |
74 |
0 |
Adobe PDF file |
View
|
32 |
Exhibit 2W: Line 132 Cross Ties Schematic (NTSB 035-012) |
4 |
0 |
Adobe PDF file |
View
|
33 |
Exhibit 2X: Healy Station and Cross Ties Valve (NTSB(008-003) |
6 |
0 |
Adobe PDF file |
View
|
34 |
Exhibit 2Y: San Francisco Control Room Logs 09-09-10 |
441 |
0 |
Adobe PDF file |
View
|
35 |
Addendum to Exhibit 2Y - Audio Enhanced Transcript of SF Control Room Logs on 09-09-10 |
441 |
0 |
Adobe PDF file |
View
|
36 |
Materials Lab - Study Report 11-089 (with 8 embedded images) |
14 |
0 |
Adobe PDF file |
View
|
37 |
Materials Lab - Study Report 11-075 (with 15 embedded images) |
13 |
0 |
Adobe PDF file |
View
|
38 |
Exhibit 2Z: (NTSB 046-001) L132 Risk Factors |
23 |
0 |
Adobe PDF file |
View
|
39 |
Exhibit 2AA: Where Did 1961 5/16-Inch Pipe on Glenview Extension Come From? (NTSB 038-004) |
2 |
0 |
Adobe PDF file |
View
|
40 |
Materials Lab - Factual Report 11-056 (with 42 embedded images) |
53 |
0 |
Adobe PDF file |
View
|
41 |
Materials Lab - Study Report 11-057 (with 1 embedded image) |
8 |
0 |
Adobe PDF file |
View
|
42 |
Exhibit 2AB: How Was Welded Pipe Entered as Seamless into the Records (NTSB 035-018) |
2 |
0 |
Adobe PDF file |
View
|
43 |
Exhibit 2AC: Is It Possible that the 5/16-Inch Pipe Purchased in 1948 and Sent to Oakland Was Used in 1956 Relocation Job (NTSB 038-003) |
2 |
0 |
Adobe PDF file |
View
|
44 |
Exhibit 2-AD: Highest Recorded Pressures on Line 132 (NTSB 004-005 & 036-003) |
27 |
0 |
Adobe PDF file |
View
|
45 |
Exhibit 2AE: Provide a List of Transmission Lines with Corresponding MAOPs in San Bruno |
2 |
0 |
Adobe PDF file |
View
|
46 |
Exhibit 2AF: NTSB_035-016 Who Manufactured the Pipe at the Accident Site and the Manufacturing Process |
16 |
0 |
Adobe PDF file |
View
|
47 |
Revised Exhibit 2-AG Overpressure Requirement RMI-06 Rev 00 and Rev 01 |
28 |
0 |
Adobe PDF file |
View
|
48 |
Exhibit 2AG: 5-Year Overpressure Requirement RMI-06 Rev 01 |
15 |
0 |
Adobe PDF file |
View
|
49 |
Exhibit 2AH: NTSB_027-002 All PG&E Over Pressures of Any Lines and Documentation |
81 |
0 |
Adobe PDF file |
View
|
50 |
Exhibit 2AI: NTSB_036-005 All Lines that PG&E Overpressures in Order to Maintain MAOP |
22 |
0 |
Adobe PDF file |
View
|
51 |
Exhibit 2AJ: Milpitas Operations & Maintenance (NTSB 033-006) |
146 |
0 |
Adobe PDF file |
View
|
52 |
Exhibit 2AK: Milpitas UPS Upgrade Project Documentation (NTSB 036-008) |
75 |
0 |
Adobe PDF file |
View
|
53 |
Exhibit 2AL: NTSB_036-008 Milpitas UPS Upgrade Project As-Builts |
19 |
0 |
Adobe PDF file |
View
|
54 |
Exhibit 2AM: Milpitas Work Clearances, August Thru September 2010 (NTSB_011-008 ) |
10 |
0 |
Adobe PDF file |
View
|
55 |
Exhibit 2AN: Cross Tie Procedures (Seasonal Settings) (NTSB 033-009) |
25 |
0 |
Adobe PDF file |
View
|
56 |
Exhibit 2AO: All Cross Tie Valves on L101,109 & 132 (NTSB 033-008) |
5 |
0 |
Adobe PDF file |
View
|
57 |
Exhibit 2AP: NTSB_008-004 & 004S1 GM 151181 and 1961 L132 Relocation Project Documentation |
9 |
0 |
Adobe PDF file |
View
|
58 |
Exhibit 2AQ: 1956 Drawings of Relocation of Line 132 GM136471 |
5 |
0 |
Adobe PDF file |
View
|
59 |
Exhibit 2AR: NTSB_035-018 PG&E Description How Welded Pipe Was entered as Seamless Pipe in GIS System |
2 |
0 |
Adobe PDF file |
View
|
60 |
Exhibit 2AS: NTSB_023-001 PG&E GIS Audit Change Log |
2 |
0 |
Adobe PDF file |
View
|
61 |
Exhibit 2AT: Listing of Seamless Pipe Greater then 24-inch Diameter (NTSB 033-001) |
8 |
0 |
Adobe PDF file |
View
|
62 |
Exhibit 2AU: Excerpts from PG&E Integrity Management Plan |
165 |
0 |
Adobe PDF file |
View
|
63 |
Exhibit 2AV: Excerpts from PG&E Risk Management Plan |
53 |
0 |
Adobe PDF file |
View
|
64 |
Exhibit 2AW: Line 132 Baseline Integrity Management Assessment |
24 |
0 |
Adobe PDF file |
View
|
65 |
Exhbit 2AX: Excerpts of PG&E ECDA Records |
35 |
0 |
Adobe PDF file |
View
|
66 |
Exhibit 2AY: CPUC 2005 and 2010 IMI Audit Items (NTSB 008-001) |
26 |
0 |
Adobe PDF file |
View
|
67 |
Exhibit 2AZ: NTSB_011-010 PG&E 1956 Journal Voucher, Material Codes and Pipeline Survey Sheet |
15 |
0 |
Adobe PDF file |
View
|
68 |
Exhibit 2BA: Excerpts of Job Files for Line 132 Work |
8 |
0 |
Adobe PDF file |
View
|
69 |
Exhibit 2BB: Excerpts from NTSB_018-002 1948 Construction of Line 132 |
5 |
0 |
Adobe PDF file |
View
|
70 |
Exhibit 2BC: Glenview Subdivision Maps Identifying Fire Damaged Properties |
3 |
0 |
Adobe PDF file |
View
|
71 |
Exhibit 2BD: Interview of Aguiar, PG&E 1-3-11 |
52 |
0 |
Adobe PDF file |
View
|
72 |
Exhibit 2BE: Interview of Armato,PG&E 1-6-11 |
14 |
0 |
Adobe PDF file |
View
|
73 |
Exhibit 2BF: Interview of Bosch, City of San Bruno 1-3-11 |
35 |
0 |
Adobe PDF file |
View
|
74 |
Exhibit 2BG: Interview of Breiz, PG&E 1-3-11 |
17 |
0 |
Adobe PDF file |
View
|
75 |
Exhibit 2BH: Interview of Brown, PG&E 1-5-11 |
32 |
0 |
Adobe PDF file |
View
|
76 |
Exhibit 2BI: Interview of Burke-Perralta, PG&E 1-6-11 |
70 |
0 |
Adobe PDF file |
View
|
77 |
Exhibit 2BJ: Interview of Ceniceros, PG&E 1-5-11 |
42 |
0 |
Adobe PDF file |
View
|
78 |
Exhibit 2BK: Interview of Daubin, PG&E 1-07-11 |
36 |
0 |
Adobe PDF file |
View
|
79 |
Exhibit 2BL: Interview of Fong, PG&E 1-06-11 |
23 |
0 |
Adobe PDF file |
View
|
80 |
Exhibit 2BM: Interview of Garriesere 1-5-11 |
14 |
0 |
Adobe PDF file |
View
|
81 |
Exhibit 2BN: Interview of Genera, PG&E 1-5-11 |
28 |
0 |
Adobe PDF file |
View
|
82 |
Exhibit 2BO: Interview of Groppetti, PG&E Contractor 1-5-11 |
40 |
0 |
Adobe PDF file |
View
|
83 |
Exhibit 2BP: Interview of Hannigan, City of San Bruno 1-03-11 |
43 |
0 |
Adobe PDF file |
View
|
84 |
Exhibit 2BQ: Interview of John Harty of D'Arcy & Harty Construction 1-3-11 |
75 |
0 |
Adobe PDF file |
View
|
85 |
Exhibit 2BR: Interview of Haynes, PG&E 1-07-11 |
22 |
0 |
Adobe PDF file |
View
|
86 |
Exhibit 2BS: Interview of Hong, PG&E 1-5-11 |
27 |
0 |
Adobe PDF file |
View
|
87 |
Exhibit 2BT: Interview of Karkazis, PG&E 1-3-11 |
54 |
0 |
Adobe PDF file |
View
|
88 |
Exhibit 2BU: Interview of Manegold, PG&E 1-7-11 |
52 |
0 |
Adobe PDF file |
View
|
89 |
Exhibit 2BV: Interview of Mitchell, PG&E 1-07-11 |
33 |
0 |
Adobe PDF file |
View
|
90 |
Exhibit 2BW: Interview of Jose Ornelas of D'Arcy & Harty Construction 1-6-11 |
101 |
0 |
Adobe PDF file |
View
|
91 |
Exhibit 2BX: Interview of Pena, PG&E 1-5-11 |
17 |
0 |
Adobe PDF file |
View
|
92 |
Exhibit 2BY: Interview of Poulo, PG&E 1-5-11 |
69 |
0 |
Adobe PDF file |
View
|
93 |
Exhibit 2BZ: Interview of Reinhardt, City of San Bruno CA, 1-3-11 |
36 |
0 |
Adobe PDF file |
View
|
94 |
Exhibit 2CA: Interview of Robertson, PG&E 1-6-11 |
16 |
0 |
Adobe PDF file |
View
|
95 |
Exhibit 2CB: Interview of Roccholz, PG&E 1-6-11 |
55 |
0 |
Adobe PDF file |
View
|
96 |
Exhibit 2CC: Shori, CAPUC 1-5-11 |
38 |
0 |
Adobe PDF file |
View
|
97 |
Exhibit 2CD: Sickinger, PG&E 1-5-11 |
39 |
0 |
Adobe PDF file |
View
|
98 |
Exhibit 2CE: Interview of Stepanian, CAPUC 1-6-11 |
19 |
0 |
Adobe PDF file |
View
|
99 |
Exhibit 2CF: Interview of Valenti, PG&E 1-4-11 |
87 |
0 |
Adobe PDF file |
View
|
100 |
Exhibit 2CG: Interview of Wagner, PG&E 1-4-11 |
26 |
0 |
Adobe PDF file |
View
|
101 |
Exhibit 2CH: Interview of Wenzel, PG&E 1-5-11 |
31 |
0 |
Adobe PDF file |
View
|
102 |
Exhibit 2CI: Interview of West, PG&E 1-4-11 |
68 |
0 |
Adobe PDF file |
View
|
103 |
Exhibit 2CJ: Interview of Wong, City of San Bruno CA, 1-3-11 |
54 |
0 |
Adobe PDF file |
View
|
104 |
Exhibit 2CK: PHMSA Advisory Bulletin ADB 11-01 |
14 |
0 |
Adobe PDF file |
View
|
105 |
Exhibit 2CL: Excerpts From PG&E Camera Inspection of Line 132, Segment 180 |
48 |
0 |
Adobe PDF file |
View
|
106 |
Exhibit 2CM: PGE Pipeline 2020 Program |
4 |
0 |
Adobe PDF file |
View
|
107 |
Exhibit 2CN: PHMSA Pipeline Mileage Data |
4 |
0 |
Adobe PDF file |
View
|
108 |
Exhibit 2CO: PG&E Operator Report - Incident and Mileage Data |
6 |
0 |
Adobe PDF file |
View
|
109 |
Exhibit 2CP: PHMSA Serious Pipeline Incident Stats 2000-2009 all |
3 |
0 |
Adobe PDF file |
View
|
110 |
Exhibit 2CQ: Transmission Onshore Significant Incidents 1990 - 2009 chart |
2 |
0 |
Adobe PDF file |
View
|
111 |
Exhibit 2CR: Transmission Serious Incidents by Cause 2000-2009 Pie Chart |
2 |
0 |
Adobe PDF file |
View
|
112 |
Exhibit 2CS: California Gas Transmission Incident Data (PHMSA) |
2 |
0 |
Adobe PDF file |
View
|
113 |
Exhibit 2CT: Age of Transmission and Hazardous Liquid Pipelines (pipelinesafetytrust) |
3 |
0 |
Adobe PDF file |
View
|
114 |
Exhibit 2CU: Age of Transmission Pipelines PGE vs Southern CA Gas |
2 |
0 |
Adobe PDF file |
View
|
115 |
Exhibit 2CV: Pipeline Rupture Site Looking North, 10 Sept 2010 IMG_0097 NTSB (Downs) |
1 |
0 |
Adobe PDF file |
View
|
116 |
Exhibit 2CW: Ruptured Pipeline Segment North End, 11 Sept 2010 IMG_0128 NTSB (Downs) |
1 |
0 |
Adobe PDF file |
View
|
117 |
Exhibit 2CX: Segment of Ruptured Pipeline Resting in Glenview Avenue, 10 Sept 2010 IMG_0098 NTSB (Downs) |
1 |
0 |
Adobe PDF file |
View
|
118 |
Exhibit 2CY Fire Damage Looking East Toward Crestmoor Canyon, 10 Sept 2010 IMG_0101 NTSB (Downs) |
1 |
0 |
Adobe PDF file |
View
|
119 |
Exhibit 2CZ: Property Damage Near Rupture Location, 11 Sept 2010 IMG_0133 NTSB (Downs) |
1 |
0 |
Adobe PDF file |
View
|
120 |
Exhibit 2DA: Photograph of Glenview Avenue Looking North, 10 Sept 2010 ((197) San Bruno Fire Dept.) |
1 |
0 |
Adobe PDF file |
View
|
121 |
Exhibit 2DB: Photograph of Glenview Avenue Looking South, 10 Sept 2010 ((198) San Bruno Fire Dept.) |
1 |
0 |
Adobe PDF file |
View
|
122 |
Exhibit 2DC: Photograph of Pipeline Fire Sept 9, 2010 (DSC06572 San Bruno Police) |
1 |
0 |
Adobe PDF file |
View
|
123 |
Exhibit 2DD: San Bruno, CA Google Earth Image Sept 11, 2010 |
1 |
0 |
Adobe PDF file |
View
|
124 |
Exhibit 2DE: San Bruno Aerial Photo on September 1, 1956 |
3 |
0 |
Adobe PDF file |
View
|
125 |
Exhibit 2DF: Interview of John Corona, PGE September 16, 2010 |
21 |
0 |
Adobe PDF file |
View
|
126 |
Exhibit 2DG: CPUC General Order 112E |
23 |
0 |
Adobe PDF file |
View
|
127 |
Exhibit 2DH: PG&E Response to CPUC 2010 IM Inspection |
26 |
0 |
Adobe PDF file |
View
|
128 |
Exhibit 2DI: PG&E Response to CPUC 10-21-10 Letter |
8 |
0 |
Adobe PDF file |
View
|
129 |
Exhibit 2DJ: CPUC 10-21-10 Letter to PG&E |
15 |
0 |
Adobe PDF file |
View
|
130 |
Exhibit 2DK: PG&E Response of 12-16-10 to CPUC May 2010 IM Audit.pdf |
3 |
0 |
Adobe PDF file |
View
|
131 |
Exhibit 2DL: CPUC 9-24-10 letter to PG&E Regarding GO 112E Audit of Peninsula Division |
48 |
0 |
Adobe PDF file |
View
|
132 |
Exhibit 2DM: CPUC 10-17-08 letter to PG&E Regarding GO 112E Audit |
4 |
0 |
Adobe PDF file |
View
|
133 |
Exhibit 2DN: CPUC Post Accident Responses to San Bruno Pipeline Explosion |
18 |
0 |
Adobe PDF file |
View
|
134 |
Exhibit 2DO: Summary of CPUC 2005 IM Audit of PG&E |
3 |
0 |
Adobe PDF file |
View
|
135 |
Exhibit 2DP: CPUC 2005 PG&E IM Audit Meeting Summary |
6 |
0 |
Adobe PDF file |
View
|
136 |
Exhibit 2DQ: PHMSA Report on "Building Safe Communities: Pipeline Risk and Its Application to Local Development" |
31 |
0 |
Adobe PDF file |
View
|
137 |
Exhibit 2DR: Congressional Hearing Pipeline Safety Public Awareness Testimony |
77 |
0 |
Adobe PDF file |
View
|
138 |
Exhibit 2DS: Journal Entries from 1948 L132 Construction |
30 |
0 |
Adobe PDF file |
View
|
139 |
Exhibit 2DT: CPUC and PG&E Correspondence Regarding the San Bruno Accident since December 16, 2010 |
72 |
0 |
Adobe PDF file |
View
|
140 |
Exhibit 2DU: PG&E Comments to PHMSA-RSPA |
38 |
0 |
Adobe PDF file |
View
|
141 |
Exhibit 2DV: 1956 Relocation Source of Pipe Material |
19 |
0 |
Adobe PDF file |
View
|
142 |
Exhibit 2DW: Geologic Hazard Evaluations |
10 |
0 |
Adobe PDF file |
View
|
143 |
Exhibit 2DX: Timeline of Events for September 9, 2010 Prepared by NTSB |
15 |
0 |
Adobe PDF file |
View
|
144 |
Exhibit 2DY: PG&E June 24, 1996 Memo Re: Remote/Automatic Valves |
5 |
0 |
Adobe PDF file |
View
|
145 |
Exhibit 2DZ: White Paper on Equivalent Safety for Alternative Valve Spacing, INGAA, November 15, 2005 |
27 |
0 |
Adobe PDF file |
View
|
146 |
Exhibit 2EA: PG&E Milpitas and SCADA Diagrams |
6 |
0 |
Adobe PDF file |
View
|
147 |
Lab Test Report of Line DFM-3Leak Between Santa Cruz & Davenport |
5 |
0 |
Adobe PDF file |
View
|
148 |
Examination of Section of 34-Inch Pipe Removed from Main 300B Near Trona. |
5 |
5 |
Adobe PDF file |
View
|
149 |
Exhibit 2EB: NTSB 014-008 CITECH Data Sept-9-2010 TO Sept-10-2010 REV-1(2 |
3 |
0 |
Adobe PDF file |
View
|
150 |
Exhibit 2EC: PG&E Presentation How Line 132 Became Listed in GIS System as Seamless Pipe |
8 |
0 |
Adobe PDF file |
View
|
151 |
Exhibit 2ED: San Bruno Gas Transmission LineRupture Investigation CPUC Data Request 069 |
61 |
0 |
Adobe PDF file |
View
|
152 |
Metallurgical Group Chairman Factual Report dated Jan. 21, 2011: 3-A |
78 |
0 |
Adobe PDF file |
View
|
153 |
Metallurgical Group Chairman Factual Report dated Feb. 9, 2011 3-B |
33 |
0 |
Adobe PDF file |
View
|
154 |
Exhibit 4A - Survival Factors Group Chairman Factual Report |
23 |
0 |
Adobe PDF file |
View
|
155 |
Exhibit 4B - Transcript of Fire Department Radio Communications |
41 |
0 |
Adobe PDF file |
View
|
156 |
Exhibit 4C - San Bruno Fire Department Incident Reports |
19 |
0 |
Adobe PDF file |
View
|
157 |
Exhibit 4D - List of Responding Fire Departments |
2 |
0 |
Adobe PDF file |
View
|
158 |
Exhibit 4E - Injury List |
2 |
0 |
Adobe PDF file |
View
|
159 |
Exhibit 4F - Federal Public Awareness Regulation |
3 |
0 |
Adobe PDF file |
View
|
160 |
Exhibit 4G - PG&E’s Summary Table for Public Awareness Messages |
2 |
0 |
Adobe PDF file |
View
|
161 |
Exhibit 4H - PG&E’s Public Awareness Program Plan |
24 |
0 |
Adobe PDF file |
View
|
162 |
Exhibit 4I - Map of Affected Neighborhood |
2 |
0 |
Adobe PDF file |
View
|
163 |
Exhibit 4J - Example of a Bill Stuffer for the Affected Public (Distribution) |
2 |
0 |
Adobe PDF file |
View
|
164 |
Exhibit 4K - Example of a Brochure for the Affected Public (Transmission) |
3 |
0 |
Adobe PDF file |
View
|
165 |
Exhibit 4L - Cover Letters for the 2009 and 2010 Mailings for Emergency Officials |
5 |
0 |
Adobe PDF file |
View
|
166 |
Exhibit 4M - Emergency Officials Mailing List |
2 |
0 |
Adobe PDF file |
View
|
167 |
Exhibit 4N - Public Liaison Workshop Invitation Letter |
2 |
0 |
Adobe PDF file |
View
|
168 |
Exhibit 4O - Organizations Invited to the Public Liaison Workshop |
3 |
0 |
Adobe PDF file |
View
|
169 |
Exhibit 4P - List of Organizations that Attended the Public Liaison Workshop |
2 |
0 |
Adobe PDF file |
View
|
170 |
Exhibit 4Q - Public Liaison Workshop Agenda |
3 |
0 |
Adobe PDF file |
View
|
171 |
Exhibit 4R - Announcement Flyer for a Responding to Gas and Electric Emergencies Seminar |
2 |
0 |
Adobe PDF file |
View
|
172 |
Exhibit 4S - List of Responding to Gas and Electric Emergencies Seminars |
2 |
0 |
Adobe PDF file |
View
|
173 |
Exhibit 4T - List of Attendees for Responding to Gas and Electric Emergencies Seminars |
2 |
0 |
Adobe PDF file |
View
|
174 |
Exhibit 4U - Example of a Brochure for Public Officials |
9 |
0 |
Adobe PDF file |
View
|
175 |
Exhibit 4V - Public Awareness Program Review Conducted in 2009 |
8 |
0 |
Adobe PDF file |
View
|
176 |
Exhibit 4W - Excerpts from American Petroleum Institute Recommended Practice 1162 |
7 |
0 |
Adobe PDF file |
View
|
177 |
Exhibit 4X - Public Awareness Program Review Conducted in 2010 |
9 |
0 |
Adobe PDF file |
View
|
178 |
Exhibit 4Y - PG&E Website Screenshot - Gas Transmission Line Information |
2 |
0 |
Adobe PDF file |
View
|
179 |
Fire 5A- Fire Scene Factual Report 11-002 |
13 |
8 |
Adobe PDF file |
View
|
180 |
Errata to Fire 5A- Fire Scene Factual Report 11-002 |
2 |
0 |
Adobe PDF file |
View
|
181 |
Fire 5B -Belmont-San Carlos Fire Department Origin and Cause Report |
5 |
0 |
Adobe PDF file |
View
|
182 |
Fire 5C-Belmont-San Carlos Fire Department Origin and Cause Narrative |
5 |
0 |
Adobe PDF file |
View
|
183 |
Human Performance 6A - Factual Report of Group Chairman |
12 |
0 |
Adobe PDF file |
View
|
184 |
Meteorology 7A - Factual Report of Group Chairman |
10 |
0 |
Adobe PDF file |
View
|
185 |
Exhibit 8A - Presentation by Mr. Geoff Foreman |
10 |
0 |
Adobe PDF file |
View
|
186 |
Exhibit 8B: Presentation by Mr. Robert Smith, PHMSA |
17 |
0 |
Adobe PDF file |
View
|
187 |
Exhibit 8C: Presentation by Mr. Charles Dippo, AGA |
14 |
0 |
Adobe PDF file |
View
|
188 |
Exhibit 8D: Presentation by Ms. Christina Sames, AGA |
13 |
0 |
Adobe PDF file |
View
|
189 |
Exhibit 8E - Table Excerpted from NACE Report |
3 |
0 |
Adobe PDF file |
View
|
190 |
Aerial photograph of accident site |
1 |
0 |
Adobe PDF file |
View
|
191 |
End-on view of ruptured pipe section |
1 |
0 |
Adobe PDF file |
View
|
192 |
Fractured ends of the pipeline and the crater resulting from the rupture |
1 |
0 |
Adobe PDF file |
View
|
193 |
NTSB investigators with ruptured pipe section |
1 |
0 |
Adobe PDF file |
View
|
194 |
NTSB investigators examining the fractured ends of the pipeline and crater |
1 |
0 |
Adobe PDF file |
View
|
195 |
Accident scene with ruptured pipe section in the foreground |
1 |
0 |
Adobe PDF file |
View
|
196 |
Accident scene with the crater in the foreground and the ruptured pipe section in the background |
1 |
0 |
Adobe PDF file |
View
|
197 |
Preliminary Report |
3 |
0 |
Adobe PDF file |
View
|
198 |
Interview of Transmission Coordinator |
41 |
0 |
Adobe PDF file |
View
|
199 |
Interview of Supervisor - SCADA and Control Group |
39 |
0 |
Adobe PDF file |
View
|
200 |
Interview of Distribution Integrity Management Program Engineer |
39 |
0 |
Adobe PDF file |
View
|
201 |
Interview of Director of Integrity Management |
45 |
0 |
Adobe PDF file |
View
|
202 |
Interview of Technical Crew Leader |
49 |
0 |
Adobe PDF file |
View
|
203 |
Interview of Gas Control Technician |
50 |
0 |
Adobe PDF file |
View
|
204 |
Interview of Gas Measurement and Control Mechanic |
62 |
0 |
Adobe PDF file |
View
|
205 |
Interview of Contractor Employed by Pacific Gas & Electric(John Groppetti) |
54 |
0 |
Adobe PDF file |
View
|
206 |
Interview of Gas System Operator |
43 |
0 |
Adobe PDF file |
View
|
207 |
Interview of Senior Distribution Specalist (Scott Robinson) |
19 |
0 |
Adobe PDF file |
View
|
208 |
Interview of Transmission and Regulation Supervisor |
28 |
0 |
Adobe PDF file |
View
|
209 |
Interview of Senior Transmission Coordinator |
35 |
0 |
Adobe PDF file |
View
|
210 |
Interview of Apprentice Gas Technician |
17 |
0 |
Adobe PDF file |
View
|
211 |
Photograph of the 28-foot-long ruptured section of pipeline |
1 |
0 |
Adobe PDF file |
View
|
212 |
Photograph of an NTSB investigator examining facture surfaces |
1 |
0 |
Adobe PDF file |
View
|
213 |
Photograph showing a view of the ruptured pipe piece with an NTSB investigator examining the facture surfaces |
1 |
0 |
Adobe PDF file |
View
|
214 |
Photograph of an NTSB investigator examining a fracture surface on a scanning electron microscope |
1 |
0 |
Adobe PDF file |
View
|
215 |
San Bruno Police Department photograph of fire taken from a nearby street. |
1 |
0 |
Adobe PDF file |
View
|
216 |
Poster Presentation |
5 |
0 |
Adobe PDF file |
View
|
217 |
Video File |
1 |
0 |
Adobe PDF file |
View
|
218 |
Public Hearing Transcript - March 1, 2011 (Day One) |
214 |
0 |
Adobe PDF file |
View
|
219 |
Public Hearing Transcript - March 2, 2011 (Day Two) |
214 |
0 |
Adobe PDF file |
View
|
220 |
Public Hearing Transcript - March 3, 2011 (Day Three) |
129 |
0 |
Adobe PDF file |
View
|
221 |
Materials Laboratory Factual Report 11-030, FBI presentation on laser scanning of pipe |
38 |
0 |
Adobe PDF file |
View
|
222 |
Materials Lab - Factual Report of Group Chairman - Errata (with 4 embedded images) |
7 |
0 |
Adobe PDF file |
View
|
223 |
Materials Lab - Factual Report of Group Chairman - Addendum 1 Errata |
4 |
0 |
Adobe PDF file |
View
|
224 |
Materials Laboratory Factual Report 11-031, 3D pdf file of pipe |
2 |
0 |
Adobe PDF file |
View
|
225 |
Materials Lab - Factual Report 11-049 (with 13 embedded images) |
21 |
0 |
Adobe PDF file |
View
|
226 |
Materials Laboratory Study Report 11-058, Finite element models for two weld geometries |
31 |
0 |
Adobe PDF file |
View
|
227 |
Materials Lab - Factual Report 11-059 |
11 |
0 |
Adobe PDF file |
View
|
228 |
Materials Lab - Factual Report 11-060 |
39 |
0 |
Adobe PDF file |
View
|
229 |
Materials Lab - Attachment 1 - PG&E Purchase Order No. 7R 183613 |
2 |
0 |
Adobe PDF file |
View
|
230 |
Materials Lab - Attachment 2 - PG&E Purchase Order No. 7R 182222 |
13 |
0 |
Adobe PDF file |
View
|
231 |
Materials Lab - Attachment 3 - Moody Engineering Co. "Inspection Order 7R-81743, Purchase Order 7R-66858, Consolidated Western Steel Corp., 30" O.D. x 3/8" Wall Line Pipe." |
39 |
0 |
Adobe PDF file |
View
|
232 |
Materials Lab - Attachment 4 - PG&E Specifcations for Pipe - Purchase Order 7R-61963 |
6 |
0 |
Adobe PDF file |
View
|
233 |
Materials Lab - Attachment 5 - PG&E Specifications for Pipe - Purchase Order 7R-66858 |
6 |
0 |
Adobe PDF file |
View
|
234 |
Materials Lab - Attachment 6 - San Bruno GT Line Incident_DR_NTSB_065-001 |
1 |
0 |
Adobe PDF file |
View
|
235 |
Materials Lab - Attachment 7 - San Bruno GT Line Incident_DR_NTSB_070-001 |
1 |
0 |
Adobe PDF file |
View
|
236 |
Materials Lab - Attachment 8 - DurableMecco E-Mail |
1 |
0 |
Adobe PDF file |
View
|
237 |
Materials Lab - Attachment 9 - Mecco Marking/M.E. Cunningham History |
2 |
0 |
Adobe PDF file |
View
|
238 |
ASCE Manual of Practice for Pipe Bursting Projects |
87 |
0 |
Adobe PDF file |
View
|
239 |
"Guidelines for Pipe Bursting" TTC Technical Report #2001.02 by Jadranka Simicevic and Raymond L. Sterling and Commissioned by the US Army Corps of Engineers |
55 |
0 |
Adobe PDF file |
View
|
240 |
Ground Vibration Associated with Pipe Bursting in Rock Conditions, Dr, Alan Atalah P.E. |
9 |
0 |
Adobe PDF file |
View
|
241 |
Survival Factors - PG&E First Responder Training: List of Individuals who Registered and/or Attended |
2 |
0 |
Adobe PDF file |
View
|
242 |
Survival Factors - PG&E Response Pertaining to the Affected Public Program Materials |
5 |
0 |
Adobe PDF file |
View
|
243 |
Survival Factors - PG&E Response Pertaining to Emergency Responder Training |
2 |
0 |
Adobe PDF file |
View
|
244 |
Survival Factors - Measuring Public Awareness Effectiveness 2007 Industry Survey |
27 |
0 |
Adobe PDF file |
View
|
245 |
Survival Factors - PG&E First Responders Meeting Sign-in Sheets from March 25, 2009 |
2 |
0 |
Adobe PDF file |
View
|
246 |
Survival Factors - PG&E First Responders Meeting Sign-in Sheet from March 25, 2010 |
1 |
0 |
Adobe PDF file |
View
|
247 |
Survival Factors - Incident Response Timeline Compiled by the City of San Bruno |
11 |
0 |
Adobe PDF file |
View
|
248 |
Survival Factors - Transcript of Fire Department Radio Communications
Beginning at 1932:26 |
55 |
0 |
Adobe PDF file |
View
|
249 |
Survival Factors - Transcript of Fire Department Radio Communications Beginning at 2115:47 |
38 |
0 |
Adobe PDF file |
View
|
250 |
Survival Factors - Transcript of Fire Department Radio Communications Beginning at 2232:41 |
33 |
0 |
Adobe PDF file |
View
|
251 |
Survival Factors - Transcript of San Bruno Police Department Communications |
35 |
0 |
Adobe PDF file |
View
|
252 |
Survival Factors - Transcript of Law Enforcement Mutual Aid Channel |
98 |
0 |
Adobe PDF file |
View
|
253 |
Human Performance Factual Report Addendum 1 |
5 |
0 |
Adobe PDF file |
View
|
254 |
Pacific Gas & Electric Co. Gas Integrity Management Plan Reports |
11 |
0 |
Adobe PDF file |
View
|
255 |
Standard Pacific Gas Line Inc. Integrity Management Plan Reports |
10 |
0 |
Adobe PDF file |
View
|
256 |
JACOBS Consultancy Report of the San Bruno Explosion Prepared for CPUC |
204 |
0 |
Adobe PDF file |
View
|
257 |
PG&E Correspondence of June 2, 2011 Regarding Resubmittal of Documents |
1 |
0 |
Adobe PDF file |
View
|
258 |
NTSB_001-002A Data Request for PG&E to Provide Pipe Mill Specifications and History |
1 |
0 |
Adobe PDF file |
View
|
259 |
NTSB_001-002A Attachment - Pipe mill specs and history |
13 |
0 |
Adobe PDF file |
View
|
260 |
NTSB_003-001 S2 WP4100-10 Clearance Procedures |
21 |
0 |
Adobe PDF file |
View
|
261 |
NTSB_004-001A Provide Pressure Reductions on Line 132 |
1 |
0 |
Adobe PDF file |
View
|
262 |
NTSB_004-005S Supplemental Data Request (DR) Regarding the Highest Recorded Pressure on Line 132 |
3 |
0 |
Adobe PDF file |
View
|
263 |
NTSB Data Request _005-001, Natural Gas Composition for Line 132 |
2 |
0 |
Adobe PDF file |
View
|
264 |
NTSB_008-007A Provide USGS Seismic Data Overlay |
1 |
0 |
Adobe PDF file |
View
|
265 |
NTSB 008-007A Attachment - Seismic Overlay |
5 |
0 |
Adobe PDF file |
View
|
266 |
NTSB_Request 009-001-S1 What is volume of gas lost on L132 |
1 |
0 |
Adobe PDF file |
View
|
267 |
NTSB_010-005-S4 Constr Spec, Stand for 1956 GMI136471 Project |
15 |
0 |
Adobe PDF file |
View
|
268 |
NTSB_Request 009-001A What is volume of gas lost on L132 |
1 |
0 |
Adobe PDF file |
View
|
269 |
NTSB Request 010-002-What is Source of GIS Information |
1 |
0 |
Adobe PDF file |
View
|
270 |
NTSB 010-005 AsBuilt Info from 1956 - Relocation GM No.13647 Brisbane 60 PO for Line 132 |
317 |
0 |
Adobe PDF file |
View
|
271 |
NTSB_Data Request #011-007A_All Pressure Charts from Facilities |
1 |
0 |
Adobe PDF file |
View
|
272 |
NTSB_011-007A_Attachment - All Pressure Charts from Facilities |
10 |
0 |
Adobe PDF file |
View
|
273 |
NTSB Request_014-006 SCADA Alarm Policy |
22 |
0 |
Adobe PDF file |
View
|
274 |
NTSB_014-008 - SCADA DATA - Alarms & Pressures |
80 |
0 |
Adobe PDF file |
View
|
275 |
NTSB_014-008 Rev1 - SCADA DATA - Pressures |
41 |
0 |
Adobe PDF file |
View
|
276 |
NTSB 033-006 PG&E’s procedures related to control set-points |
126 |
0 |
Adobe PDF file |
View
|
277 |
NTSB_033-007 Provide documentation Regulating Equip Set points |
44 |
0 |
Adobe PDF file |
View
|
278 |
NTSB Data Request #035-004, Earthquake Engineering Evaluation Question |
1 |
0 |
Adobe PDF file |
View
|
279 |
NTSB Data Request #035-004, Attachment to Response - American Society of Civil Engineers Earthquake Report |
11 |
0 |
Adobe PDF file |
View
|
280 |
NTSB Data Request #035-005, How do Seismic Events Relate to Integrity Management |
2 |
0 |
Adobe PDF file |
View
|
281 |
NTSB_035-009 – Project 130004 Excerpts.pdf |
10 |
0 |
Adobe PDF file |
View
|
282 |
NTSB_036-004 Rev2 – 2003 & 2008 Pressure readings |
15 |
0 |
Adobe PDF file |
View
|
283 |
NTSB_036-04S1 – Mile Points of Pressure Readings |
2 |
0 |
Adobe PDF file |
View
|
284 |
NTSB 036-004S - Peninsula Map and Milepoints of Pressure Readings |
1 |
0 |
Adobe PDF file |
View
|
285 |
NTSB_036-009 PGE Actions on USA Tickets |
22 |
0 |
Adobe PDF file |
View
|
286 |
NTSB_038-001 How Was Pipe Reconditioned? |
1 |
0 |
Adobe PDF file |
View
|
287 |
NTSB_044-001 Clearance Training |
1 |
0 |
Adobe PDF file |
View
|
288 |
NTSB_050-005 Clearance for 5-year pressure increase on line 132 |
16 |
0 |
Adobe PDF file |
View
|
289 |
NTSB_053-001 Control Room Procedures |
33 |
0 |
Adobe PDF file |
View
|
290 |
NTSB_053-002 Dispatch Center Procedures |
219 |
0 |
Adobe PDF file |
View
|
291 |
NTSB_053-003 Gas Control and Dispatch Coordination |
12 |
0 |
Adobe PDF file |
View
|
292 |
NTSB_053-007 - Pressures On All Incoming Lines |
2 |
0 |
Adobe PDF file |
View
|
293 |
NTSB_053-008 - Upstream Station Pressures into Milpitas |
2 |
0 |
Adobe PDF file |
View
|
294 |
NTSB_053-009 - Valve States SCADA Data |
79 |
0 |
Adobe PDF file |
View
|
295 |
NTSB_053-012 - Operational Diagram Key |
4 |
0 |
Adobe PDF file |
View
|
296 |
NTSB Data Request 054-001 Request for Pressure Data |
1 |
0 |
Adobe PDF file |
View
|
297 |
NTSB Data Request 054-008 Attachment - TRE Report |
36 |
0 |
Adobe PDF file |
View
|
298 |
NTSB_054-010 - Number of Gas Employees Qualified to Operate Valves |
1 |
0 |
Adobe PDF file |
View
|
299 |
NTSB 055-001, Answer to what lines were installed by PG&E? |
4 |
0 |
Adobe PDF file |
View
|
300 |
NTSB Data Request #055-003, Pipe Manufacturing Threats |
2 |
0 |
Adobe PDF file |
View
|
301 |
NTSB_056-001 Volume Released Calculations or Models Used |
9 |
0 |
Adobe PDF file |
View
|
302 |
NTSB_056-004 - Volume Released Flow Rate At Time Of Rupture Split By North And South.pdf |
2 |
0 |
Adobe PDF file |
View
|
303 |
NTSB Data Request #057-005, Question on Raising Pipeline Pressures |
1 |
0 |
Adobe PDF file |
View
|
304 |
NTSB_058-002 Pressure Trends and Why Valves Were Commanded Open.pdf |
1 |
0 |
Adobe PDF file |
View
|
305 |
NTSB 058-004 - PLS7A and PLS7B Pressure SCADA Data |
137 |
0 |
Adobe PDF file |
View
|
306 |
NTSB_058-007 Chart Recorders and Which Lines They Serve |
1 |
0 |
Adobe PDF file |
View
|
307 |
NTSB 064-002 – 2008 Pressure readings in 20-Sec Intervals |
43 |
0 |
Adobe PDF file |
View
|
308 |
NTSB_064-006 - SCADA flows in 20-sec intervals |
181 |
0 |
Adobe PDF file |
View
|
309 |
NTSB 064-005 - SCADA Incoming Pressures in 20-Second Intervals |
139 |
0 |
Adobe PDF file |
View
|
310 |
NTSB Data Request #054-008 for Information on Outside Force on Pipeline |
1 |
0 |
Adobe PDF file |
View
|
311 |
NTSB 068-001, Line 132 Risk calculation Figures for 2009 & 2010 |
1 |
0 |
Adobe PDF file |
View
|
312 |
NTSB 069-001 Confirmation that Sullivan was not back feeding. |
1 |
0 |
Adobe PDF file |
View
|
313 |
NTSB 071-002 - Estimate of Lost Gas and Total Cost of the San Bruno Accident |
2 |
0 |
Adobe PDF file |
View
|
314 |
NTSB 073-001 Monitor Valve Setpoints |
2 |
0 |
Adobe PDF file |
View
|
315 |
NTSB 080-007 Was Replacement Pipe used for the 12-ft & 40-ft Ssections Pretested |
11 |
0 |
Adobe PDF file |
View
|
316 |
NTSB 083-001 PG&E Construction Specs for 1948 (GM98015) Project - Crystal Springs to Martin Stn 30_24 20 |
51 |
0 |
Adobe PDF file |
View
|
317 |
NTSB 083-001 PG&E Construction Specs for 1948 (GM98015) Project - Martin Station to Potrero 24 20 |
24 |
0 |
Adobe PDF file |
View
|
318 |
Interview Transcript of PG&E Technical Crew Leader (Peter Beck) |
49 |
0 |
Adobe PDF file |
View
|
319 |
Interview of PG&E Gas Control Technician (Oscar Martinez) |
50 |
0 |
Adobe PDF file |
View
|
320 |
Interview of PG&E Gas Mechanic (Joe Joaquim) |
32 |
0 |
Adobe PDF file |
View
|
321 |
Interview Transcript of Pipe Manufacturer Employee (Massaglia) |
38 |
0 |
Adobe PDF file |
View
|
322 |
Interview of PG&E former Consultant and Records Manager (Larry Medina) |
80 |
0 |
Adobe PDF file |
View
|
323 |
Transcribed Concord Dispatch Logs |
256 |
0 |
Adobe PDF file |
View
|
324 |
Water Utilities Division Work Order for Huntington Avenue |
1 |
0 |
Adobe PDF file |
View
|
325 |
Water Utilities Division Work Order of 1989 for Sixth Street |
4 |
0 |
Adobe PDF file |
View
|
326 |
Geologic Hazards Report for Lines 109 and 132 in San Bruno |
49 |
0 |
Adobe PDF file |
View
|
327 |
Crestmoor Canyon Geotechnical Investigation Report |
59 |
0 |
Adobe PDF file |
View
|
328 |
California PUC General Order 112 Effective as of January, 1961 |
27 |
0 |
Adobe PDF file |
View
|
329 |
The Shake Out Scenario - Supplemental Study for the US Geological Survey |
12 |
0 |
Adobe PDF file |
View
|
330 |
Shaking Intensity Map of the San Bruno Area |
1 |
0 |
Adobe PDF file |
View
|
331 |
Guidelines for the Design of Buried Steel Pipe |
83 |
0 |
Adobe PDF file |
View
|
332 |
San Bruno Water Leak Location Map from 2000-2007 |
1 |
0 |
Adobe PDF file |
View
|
333 |
Remote Capability of Valves Summary |
12 |
0 |
Adobe PDF file |
View
|
334 |
Environmental Analysis of Gas Transmission Pipelines 109 and 132 |
49 |
0 |
Adobe PDF file |
View
|
335 |
PG&E Presentation to San Bruno Planning Commission |
60 |
0 |
Adobe PDF file |
View
|
336 |
Glenview Water Leak Location Map |
1 |
0 |
Adobe PDF file |
View
|
337 |
Crestmoor Park No 7 Improvement Plans |
2 |
0 |
Adobe PDF file |
View
|
338 |
2008 Sewer Installation Construction Documents |
16 |
0 |
Adobe PDF file |
View
|
339 |
PGE Inspectors Worksheet from 2008 Sewer Repair |
1 |
0 |
Adobe PDF file |
View
|
340 |
San Bruno Blast Site Aerial View and Survey 6 - 20 - 2011 |
2 |
0 |
Adobe PDF file |
View
|
341 |
Photograph of the (MIMIC) Control Panel from the Milipitas Terminal |
1 |
0 |
Adobe PDF file |
View
|
342 |
Blast Site Survey drawing from City of San Bruno |
1 |
0 |
Adobe PDF file |
View
|
343 |
Leak in Gas Line DFM-3 Between Santa Cruz and Davenport |
5 |
5 |
Adobe PDF file |
View
|
344 |
Sketch by Jose Ornelas |
1 |
0 |
Adobe PDF file |
View
|
345 |
Sketch by John Harty |
1 |
0 |
Adobe PDF file |
View
|
346 |
May 20, 2011 Letter via Email from PG&E to NTSB identifying and attaching newly discovered documents from 1988. |
1 |
0 |
Adobe PDF file |
View
|
347 |
Attachment to PG&E May 20, 2011 Letter - Shipping Paper for Line 132 Dated October 28, 1988 |
1 |
0 |
Adobe PDF file |
View
|
348 |
June 30,1974 Correspondence of Pipe from Line 300B |
2 |
0 |
Adobe PDF file |
View
|
349 |
Attachment to PG&E May 20,2011 Letter - Leak Survey, Inspection, and Repair Report for Line 132 Failure in 1988. |
2 |
0 |
Adobe PDF file |
View
|
350 |
Attachment to PG&E May 20, 2011 Letter - Pipeline 132 Shutdown Meeting Notes of November 8, 1988 |
2 |
0 |
Adobe PDF file |
View
|
351 |
Attachment to PG&E May 20, 2011 Letter - Photograph of PG&E Pipeline 132 from November 2, 1988 |
1 |
0 |
Adobe PDF file |
View
|
352 |
Attachment to PG&E May 20, 2011 Letter - Cost Accounting report for 1988 Failure on Line 132 |
49 |
0 |
Adobe PDF file |
View
|
353 |
City of San Bruno Submission for San Bruno Accident |
12 |
0 |
Adobe PDF file |
View
|
354 |
June 17, 2011, Cover Letter of PG&E Submission for San Bruno Accident |
1 |
0 |
Adobe PDF file |
View
|
355 |
Cover Letter of CPUC Submission for San Bruno Accident |
1 |
0 |
Adobe PDF file |
View
|
356 |
PG&E Submission for San Bruno Accident |
13 |
0 |
Adobe PDF file |
View
|
357 |
CPUC Submission for San Bruno Accident |
10 |
0 |
Adobe PDF file |
View
|
358 |
International Brotherhood of Electrical Workers Local 1245 Email Submission for San Bruno Accident |
4 |
0 |
Adobe PDF file |
View
|
359 |
Engineers and Scientists of California Local 20 Email Submission for San Bruno Accident |
1 |
0 |
Adobe PDF file |
View
|
360 |
Rancho Cordova Pipeline and Operations Group Chairmans Factual Report |
11 |
0 |
Adobe PDF file |
View
|
361 |
Rancho Cordova CPUC Fresno Audit and PG&E Response |
7 |
0 |
Adobe PDF file |
View
|
362 |
Rancho Cordova Emergency Response Group Chairmans Factual Report |
11 |
0 |
Adobe PDF file |
View
|
363 |
PG&E Map of Line 132 in Accident Area |
1 |
0 |
Adobe PDF file |
View
|
364 |
Results of Video Inspection of 22-inch, Line 109 |
5 |
5 |
Adobe PDF file |
View
|
365 |
NTSB_037-005-S1 with Respect to Hydrotesting |
13 |
0 |
Adobe PDF file |
View
|
366 |
San Bruno GT Line Incident_DR_NTSB_050-001 Engineering Doc Spec |
3 |
0 |
Adobe PDF file |
View
|
367 |
San Bruno NTSB_050-002 as built drawing new materials |
1 |
0 |
Adobe PDF file |
View
|
368 |
San Bruno NTSB_050-003 Material Codes List |
500 |
0 |
Adobe PDF file |
View
|
369 |
San Bruno GT Line Incident_DR_NTSB-050-005 Comb |
31 |
0 |
Adobe PDF file |
View
|
370 |
Metallurgical Evaluation of Cracking in Line 109 Seam Welds |
12 |
0 |
Adobe PDF file |
View
|
371 |
San Bruno GT Line Incident_DR_NTSB_050-006 Pipeline Installation Dates |
1 |
0 |
Adobe PDF file |
View
|
372 |
San Bruno NTSB_053-005 SCADA Volumetric Flow in hours |
357 |
0 |
Adobe PDF file |
View
|
373 |
San Bruno GT Line DR_NTSB_053-006 SCADA Volumetric flow rates entering Milpital and Martin in 20 Seconds |
463 |
0 |
Adobe PDF file |
View
|
374 |
NTSB April Interview of SCADA Control Group Supervising Engineer |
237 |
0 |
Adobe PDF file |
View
|
375 |
IBEW1245 Submission |
4 |
0 |
Adobe PDF file |
View
|
376 |
San Bruno GT Line Incident_DR_NTSB_054-004 |
2 |
0 |
Adobe PDF file |
View
|
377 |
San Bruno GT Line Incident_DR_NTSB_055_004-Amended-2 |
15 |
0 |
Adobe PDF file |
View
|
378 |
San Bruno GT Line Incident_DR_NTSB_056-005 |
61 |
0 |
Adobe PDF file |
View
|
379 |
San Bruno GT Line Incident_DR_NTSB_057-003 |
1 |
0 |
Adobe PDF file |
View
|
380 |
Metallurgical Analysis of Leaking 16-Inch Line 402 |
2 |
0 |
Adobe PDF file |
View
|
381 |
San Bruno GT Line Incident_DR_NTSB_058-003 |
1 |
0 |
Adobe PDF file |
View
|
382 |
Transcribed Concord Dispatch Logs Submitted by PG&E |
292 |
0 |
Adobe PDF file |
View
|
383 |
San Francisco Control Room Transcripts Submitted by PG&E |
691 |
0 |
Adobe PDF file |
View
|
384 |
San Bruno GT Line Incident_DR_NTSB_058-008 |
47 |
0 |
Adobe PDF file |
View
|
385 |
San Bruno GT Line Incident_DR_NTSB_058-024 |
2 |
0 |
Adobe PDF file |
View
|
386 |
The Peninsula Transmission System |
3 |
0 |
Adobe PDF file |
View
|
387 |
San Bruno GT Line Incident_DR_NTSB_061-001 |
23 |
0 |
Adobe PDF file |
View
|
388 |
CPUC Class Location Study |
14 |
0 |
Adobe PDF file |
View
|
389 |
Root Cause Analysis of Girth Weld Leak |
3 |
0 |
Adobe PDF file |
View
|
390 |
PG&E Transmission Pipeline Statistics |
4 |
0 |
Adobe PDF file |
View
|
391 |
Overpressure Protection Setpoints for Line 132 |
4 |
0 |
Adobe PDF file |
View
|
392 |
Construction Quality Control and Quality Assurance Standards for Relocation of Segment 180 in 1956 |
16 |
0 |
Adobe PDF file |
View
|
393 |
San Bruno Sewer Work Video |
1 |
0 |
Adobe PDF file |
View
|
394 |
D'Arcy and Harty Sewer Contractor Statement Regarding Pipe Bursting |
7 |
0 |
Adobe PDF file |
View
|
395 |
Historical Line 132 SCADA pressure readings from 2002 to Dec 31 2010 |
1029 |
0 |
Adobe PDF file |
View
|
396 |
SCADA Data from Martin Station from Sept 9 to 10 |
37 |
0 |
Adobe PDF file |
View
|
397 |
Rollingwood II Sewer Photo |
1 |
0 |
Adobe PDF file |
View
|
398 |
Historical Flow data for Station Flowmeters from 2008 to 2010 |
214 |
0 |
Adobe PDF file |
View
|
399 |
NTSB 018 002 GMG Estimate Progress Reports Job Stories |
195 |
0 |
Adobe PDF file |
View
|
400 |
Operations Factual Report Addendum |
118 |
3 |
Adobe PDF file |
View
|