Title |
Pgs |
Photo |
Type |
File |
1 |
Operations 2 - Group Chairman Factual Report |
26 |
0 |
Adobe PDF file |
View
|
2 |
Operations 2 - Group Chairman Factual Report - Attachment 1 |
40 |
0 |
Adobe PDF file |
View
|
3 |
Operations 2 - Group Chairman Factual Report - Attachment 2 |
13 |
0 |
Adobe PDF file |
View
|
4 |
Operations 2 - Group Chairman Factual Report - Attachment 3 |
23 |
0 |
Adobe PDF file |
View
|
5 |
Operations 2 - Group Chairman Factual Report - Attachment 4 |
13 |
0 |
Adobe PDF file |
View
|
6 |
Operations 2 - Group Chairman Factual Report - Attachment 5 |
2 |
0 |
Adobe PDF file |
View
|
7 |
Operations 2 - Group Chairman Factual Report - Attachment 6 |
35 |
0 |
Adobe PDF file |
View
|
8 |
Operations 2 - Group Chairman Factual Report - Attachment 7 |
8 |
0 |
Adobe PDF file |
View
|
9 |
Operations 2 - Group Chairman Factual Report - Attachment 8 |
3 |
0 |
Adobe PDF file |
View
|
10 |
Operations 2 - Group Chairman Factual Report - Attachment 9 |
7 |
0 |
Adobe PDF file |
View
|
11 |
Operations 2 - Group Chairman Factual Report - Attachment 10 |
2 |
0 |
Adobe PDF file |
View
|
12 |
Operations 2 - Group Chairman Factual Report - Attachment 11 |
2 |
0 |
Adobe PDF file |
View
|
13 |
Operations 2 - Group Chairman Factual Report - Attachment 12 |
3 |
0 |
Adobe PDF file |
View
|
14 |
Operations 2 - Group Chairman Factual Report - Attachment 13 |
5 |
0 |
Adobe PDF file |
View
|
15 |
Operations 2 - Group Chairman Factual Report - Attachment 14 |
2 |
0 |
Adobe PDF file |
View
|
16 |
Operations 2 - Group Chairman Factual Report - Attachment 15 |
3 |
0 |
Adobe PDF file |
View
|
17 |
Operations 2 - Group Chairman Factual Report - Attachment 16 |
2 |
0 |
Adobe PDF file |
View
|
18 |
Operations 2 - Group Chairman Factual Report - Attachment 17 |
23 |
0 |
Adobe PDF file |
View
|
19 |
Operations 2 - Group Chairman Factual Report - Addendum 1 |
6 |
0 |
Adobe PDF file |
View
|
20 |
Operations 2 - Addendum 1 - Attachment 1 |
2 |
0 |
Adobe PDF file |
View
|
21 |
Operations 2 - Addendum 1 - Attachment 2 |
8 |
0 |
Adobe PDF file |
View
|
22 |
Operations 2 - Addendum 1 - Attachment 3 |
17 |
0 |
Adobe PDF file |
View
|
23 |
Operations 2 - Addendum 1 - Attachment 4 |
4 |
0 |
Adobe PDF file |
View
|
24 |
ATC 3 - Group Chairman Factual Report |
27 |
0 |
Adobe PDF file |
View
|
25 |
ATC 3 - Sound Spectrum Study |
2 |
0 |
Adobe PDF file |
View
|
26 |
ATC 3 - Report Regarding the Use of Oxygen Masks |
4 |
0 |
Adobe PDF file |
View
|
27 |
Maintenance Records 11 - Group Chairman Factual Report |
13 |
0 |
Adobe PDF file |
View
|
28 |
Maintenance Records 11 - Attachment 1 |
117 |
0 |
Adobe PDF file |
View
|
29 |
Maintenance Records 11 - Attachment 2 |
7 |
0 |
Adobe PDF file |
View
|
30 |
Maintenance Records 11 - Attachment 3 |
2 |
0 |
Adobe PDF file |
View
|
31 |
Maintenance Records 11 - Attachment 4 |
11 |
0 |
Adobe PDF file |
View
|
32 |
Maintenance Records 11 - Attachment 5 |
26 |
0 |
Adobe PDF file |
View
|
33 |
Maintenance Records 11 - Attachment 7 |
5 |
0 |
Adobe PDF file |
View
|
34 |
Maintenance Records 11 - Attachment 8 |
9 |
0 |
Adobe PDF file |
View
|
35 |
Maintenance Records 11 - Attachment 9 |
3 |
0 |
Adobe PDF file |
View
|
36 |
Maintenance Records 11 - Attachment 10 |
3 |
0 |
Adobe PDF file |
View
|
37 |
Maintenance Records 11 - Sunjet Work Order No. 6056 |
28 |
0 |
Adobe PDF file |
View
|
38 |
Maintenance Records 11 - Sunjet Work Order No. 5985 |
18 |
0 |
Adobe PDF file |
View
|
39 |
Maintenance Records 11 - Sunjet Work Order No. 6009 |
60 |
0 |
Adobe PDF file |
View
|
40 |
Maintenance Records 11 - Sunjet Work Order No. 5929 |
31 |
0 |
Adobe PDF file |
View
|
41 |
Maintenance Records 11 - Sunjet Work Order No. 5895 |
44 |
0 |
Adobe PDF file |
View
|
42 |
Maintenance Records 11 - Sunjet Work Order No. 5836 |
28 |
0 |
Adobe PDF file |
View
|
43 |
Maintenance Records 11 - Sunjet Work Order No. 5848 |
28 |
0 |
Adobe PDF file |
View
|
44 |
Maintenance Records 11 - Sunjet Work Order No. 5829 |
69 |
0 |
Adobe PDF file |
View
|
45 |
Maintenance Records 11 - Sunjet Work Order No. 5784 |
61 |
0 |
Adobe PDF file |
View
|
46 |
Maintenance Records 11 - Sunjet Work Order No. 5776 |
60 |
0 |
Adobe PDF file |
View
|
47 |
Maintenance Records 11 - Sunjet Work Order No. 5771 |
5 |
0 |
Adobe PDF file |
View
|
48 |
Maintenance Records 11 - Sunjet Work Order No. 5905 |
4 |
0 |
Adobe PDF file |
View
|
49 |
Maintenance Records 11 - Sunjet Work Order No. 5974 |
43 |
0 |
Adobe PDF file |
View
|
50 |
Maintenance Records 11 - Sunjet Work Order No. 5875 |
65 |
0 |
Adobe PDF file |
View
|
51 |
Cockpit Voice Recorder 12 - Group Chairman Factual Report |
8 |
0 |
Adobe PDF file |
View
|
52 |
Cockpit Voice Recorder 12 - Sound Spectrum Study |
4 |
0 |
Adobe PDF file |
View
|
53 |
Cockpit Voice Recorder 12 - Addendum to Sound Spectrum Study |
15 |
0 |
Adobe PDF file |
View
|
54 |
Airworthiness 13 - Group Chairman Factual Report |
32 |
0 |
Adobe PDF file |
View
|
55 |
Airworthiness 13 - Attachment 1 - Aircraft Wreckage Distribution |
4 |
0 |
Adobe PDF file |
View
|
56 |
Airworthiness 13 - Attachment 2 - Configuration Drawings, Learjet Model 35 |
41 |
0 |
Adobe PDF file |
View
|
57 |
Airworthiness 13 - Attachment 3 - Honeywell, Inc. (Engine) Teardown Report No. 21-11090 |
187 |
0 |
Adobe PDF file |
View
|
58 |
Airworthiness 13 - Attachment 4 - Liquid Technology Corporation, Oxygen (Source) Tests |
2 |
0 |
Adobe PDF file |
View
|
59 |
Airworthiness 13 - Attachment 5 - Learjet 35/36 Pilot's Manual, Figure 3-8, Schematic of Oxygen System |
2 |
0 |
Adobe PDF file |
View
|
60 |
Airworthiness 13 - Attachment 6 - Digital Photograph Oxygen Bottle Regulator Pre-flight Inspection |
2 |
0 |
Adobe PDF file |
View
|
61 |
Airworthiness 13 - Attachment 7 - Learjet 35/36 AFM, Oxygen Duration Tables (ZMR, 6600214 Crew Masks) |
2 |
0 |
Adobe PDF file |
View
|
62 |
Airworthiness 13 - Attachment 8 - Mod Valve (P/N 3213736-1-1, S/N P-247 Functional Test |
2 |
0 |
Adobe PDF file |
View
|
63 |
Airworthiness 13 - Attachment 9 - Photograph, Windshield Anti-Ice Shutoff Valve |
1 |
0 |
Adobe PDF file |
View
|
64 |
Airworthiness 13 - Attachment 9 - Photo 1. Windshield Anti-Ice (Defog) Shutoff Valve, beside an exemplar valve. Note the actuator pointer in the closed position. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
65 |
Airworthiness 13 - Attachment 10 - Photographs, Flow Control Valve (with Exemplar, Open, Closed) |
1 |
0 |
Adobe PDF file |
View
|
66 |
Airworthiness 13 - Attachment 10 - Photo 1. Flow Control Valve, beside an exemplar valve. Note the missing (upper) actuator housing and pilot regulator assembly. Note the relieved valve spring. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
67 |
Airworthiness 13 - Attachment 10 - Photo 2. Flow Control Valve. Note the actuator diaphragm/spring cup assembly displaced away from the valve body (i.e. clear of the lower actuator housing) after the valve has been manually opened. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
68 |
Airworthiness 13 - Attachment 10 - Photo 3. Flow Control Valve. Note the position of the valve as recovered (i.e. closed). Note the lower actuator housing crushed inward into the actuator diaphragm/spring cup assembly. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
69 |
Airworthiness 13 - Attachment 11 - Learjet 35 MM Chapter 21-30-00, Figure 3, Pressurization System Schematic |
2 |
0 |
Adobe PDF file |
View
|
70 |
Airworthiness 13 - Attachment 12 - Sunjet Aviation, Inc. Statement, Oxygen System Pressure at Takeoff |
2 |
0 |
Adobe PDF file |
View
|
71 |
Airworthiness 13 - Attachment 13 - A/C Flight Log Information Sheet, N47BA (8/11/99 - 10/23/99) |
3 |
0 |
Adobe PDF file |
View
|
72 |
Airworthiness 13 - Attachment 14 - Photographs, Oxygen Pressure Gauge (Needle Slaps) |
1 |
0 |
Adobe PDF file |
View
|
73 |
Airworthiness 13 - Attachment 14 - Photo 1. Oxygen Pressure Gauge. Viewed at 7.5x magnification. Note the needle slaps (marks) below the lowest scale reading of 0 PSI. Needle rotated slightly before examination. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
74 |
Airworthiness 13 - Attachment 14 - Photo 2. Oxygen Pressure Gague. Needle slaps more apparent when viewed under 20x magnification. (NTSB) |
1 |
0 |
Adobe PDF file |
View
|
75 |
Airworthiness 13 - Attachment 15 - Flow Control Valve Evaluation (Mechanical Failure Modes) |
20 |
0 |
Adobe PDF file |
View
|
76 |
Airworthiness 13 - Attachment 16 - B/E Aerospace, Inc. Document No. 3500-00-04 Rev. A00 |
27 |
0 |
Adobe PDF file |
View
|
77 |
Airworthiness 13 - Attachment 17 - Learjet 35 Analysis, Predicted Cabin Pressurization Effects with Zero Inflow |
6 |
0 |
Adobe PDF file |
View
|
78 |
Airworthiness 13 - Attachment 18 - Learjet 35 Analysis, Predicted Cabin Pressure Effects Due to Inflow Valve Closure During Ascent |
27 |
0 |
Adobe PDF file |
View
|
79 |
Airworthiness 13 - Attachment 19 - FAA-SCR, Learjet Model 35/36 Pressurization and Oxygen Systems |
39 |
0 |
Adobe PDF file |
View
|
80 |
Airworthiness 13 - Attachment 20 - Learjet 35 MM Chapter 21-30-00, Cabin Leakage/Pressurization Checks |
21 |
0 |
Adobe PDF file |
View
|
81 |
Airworthiness 13 - Attachment 21 - Bombardier Aerospace (Learjet) Flight Test Report No. 5428 |
27 |
0 |
Adobe PDF file |
View
|
82 |
Radar Data Study |
13 |
0 |
Adobe PDF file |
View
|
83 |
FAA Status Report on Learjet Special Certification Review Recommendations |
9 |
0 |
Adobe PDF file |
View
|
84 |
Party Submission of Sunjet Aviation, Inc. to the National Transportation Safety Board |
16 |
0 |
Adobe PDF file |
View
|
85 |
Audio Tape - A magnetic tape that was found at the accident site |
2 |
0 |
Adobe PDF file |
View
|
86 |
Two 8MM Gun Camera Films from Two Oklahoma Air National Guard F-16 Fighters |
1 |
0 |
Adobe PDF file |
View
|
87 |
Contact and location for obtaining copies of Audio Tapes. |
1 |
0 |
Adobe PDF file |
View
|